| Model | 2502-03 | 2502-02 | 2502-01 |
| Type | Displacement | Velocity | Acceleration |
| Full scale range | 200ƒÊmP-P@ | 50mm/sRMS | 100m/s2Peak |
| Measuring range | 1“`110“ of Full scale | ||
| Output current | 4 to 20mA/0 to FS | ||
| Frequency range | 10`500Hz | 10`1000Hz | 5`1000Hz |
| Linearity | Within 1“ | ||
| Accuracy | Within 5“ (80Hz,1/2 Full scale,20Ž) | ||
| Transverse sensitivity | Less than 5“ | ||
| Driving voltage | 9`28V DC | ||
| Warming up time | 10sec. approx | ||
| Ambient temperature | -20Ž to +60Ž | ||
| Protection | IP64 | ||
| Vibration limit | 200m/s2 for continuous 1000m/s2 for shock | ||
| Resonant frequency | 5kHz approx | ||
| Withstand voltage | AC1500V 1minute | ||
| Output cable | 3m pig tale (VCTF2~0.75‚‚‚Q) | ||
| Dimensions | ƒÓ45~H45mm | ||
| Weight | 105g without cable | ||
| Accessories | Setscrew M6 lengh=10 | ||
| Option | Digital monitor 2590 Mouning base | ||